KEW ยินดีให้บริการหลังการขายลูกค้าทุกท่าน

บริการหลังการขาย

KEW 2060BT

TEST AND MEASURING INSTRUMENT


Clamp Power Meter KEW 2060BT

  • Current up to 1000A rms
  • Voltage up to 1000V rms
  • Harmonics up to 30th
  • KEW 2060BT has a newly designed special jaw shape for using at a large busbar Extremely large jaw with tear drop shape can clamp a large busbar with safe
    (Conductor size 75mm, Busbar 80mm x 30mm)
 
M10_10_Phi_75
F01_Backlight
F06_Memory_no
F08_Bluetooth
F09_USB_no
F13_EPS_no
S09_TrueRMS
S07_Cat4
S05_KewConnect
S03_CE

Specifications

1.Various measurement functions

  • Measurements of current, voltage, power, harmonics and phase detection are possible.
  • True RMS: Indicates a correct value at the distorted waveform.
  • Functions of PEAK, MAX, MIN, AVG are available.
    Easy to check the temporal change in the power source.
  • LCD can display simultaneously the values of voltage and frequency or power and power factor.

 

2.Power measurement

Power measurement on any wiring system is possible.

KEW 2060BT can perform Single-phase 2-Wire / Single-phase 3-Wire and balance and unbalance measurements of Three-phase 3-Wire / Three-phase 4 Wire. The double display can simultaneously show many parameters like W & PF, W & deg, W & VA, W & Var, V & A, etc.

 

Various parameters such as active/reactive/apparent power, power factor, phase differences (1P2W only) which are required for the power measurement can be measured.

Total 3-phase power can be measured in simple steps. 

By setting the CT and VT ratio and measuring the secondary side of the transformation, the primary side value can be obtained.

 

 

3.Harmonics measurement

Harmonics of the voltage and current, which cause various failures at the field, can be measured.
It is possible to measure and show each voltage and current harmonics up to 30th.
Total harmonics distortion factor is in two types of THD-R and THD-F. Each degree of harmonics can be shown on the LCD of the tester. Both the current value (or voltage value) and the content ratio can be displayed on the same screen.

 

4.Phase detection

 

5.Connectivity

  • Dedicated Application "KEW Power*" supports both Android™ and iOS.
  • LCD display can be checked at the smart devices.
  • Measured values and graphs can be stored with a press of a button.
  • Voltage and current can be shown in the waveform display. Existence of the harmonics can be found easy.
  • Threshhold of each measured value can be set at the applicaion, and PASS and FAIL judgement is possible.

 

Measurement Data Monitoring Application "KEW Power*"

            It is available for free in the Google Play Store and App Store.
            Please search "KEW Power"
            Communication charge may be incurred separately to download application.

               

  • Supporting Android™ Ver. 8 to 15
  • Supporting iOS 10.0 or later

 

 Wiring connections  1P2W, 1P3W, 3P3W, 3P4W
 Measurements and  parameters

 Voltage, Current, Frequency, Active power, Reactive power,
 Apparent power, Power factor(cosθ), Phase angle,
 Harmonics(THD-R/THD-F), Phase rotation

AC Voltage
 
 Range  1000V
 Accuracy

 ±0.7%rdg±3dgt (40.0~70.0Hz)
 ±0.3%rdg±5dgt (70.1~1KHz)

 Crest factor  1.7 or less
AC Current
 
 Range  40.00/400.0/1000A (Auto-ranging)
 Accuracy

 ±1.0%rdg±3dgt (40.0~70.0Hz)
 ±2.0%rdg±5dgt (70.1~1kHz)

 Crest factor

 3 or less on 40.00A/400.0A range,
 3 or less 1500A peak on 1000A range

Frequency
 
 Display range  40.0~999.9Hz
 Accuracy  ±0.3%rdg±3dgt
Active power
 
 Range  40.00/400.0/1000kW (Auto-ranging)
 Accuracy

 ±1.7%rdg±5dgt (PF1, sine wave, 45~65Hz)
 influence of phase angle within ±3.0°

Apparent power
 
 Range  40.00/400.0/1000kVA (Auto-ranging)
Reactive power
 
 Range  40.00/400.0/1000kVar (Auto-ranging)
Power factor
 
 Display range  -1.000~0.000~1.000
Phase angle(1P2W only)
 
 Display range  -180.0~0.0~+179.9
Harmonics
 
 Analysis order  1st~30th order
 Accuracy

 ±5.0%rdg±10dgt (1~10th)
 ±10%rdg±10dgt (11~20th)
 ±20%rdg±10dgt (21~30th)

 Phase rotation  ACV 80~1100V (45~65Hz)
 Other functions  MAX/MIN/AVG/PEAK, Data hold, Back light, Auto power off
General
 
 Communication interface

 Bluetooth®5.0,
 Android™5.0 or more, iOS 10.0 or more ※1

 Power source LR6 (AA) (1.5V) ×2
 Continuous measuring time  Approx. 58 hours
 Conductor size  φ75 mm (max) and busbar of 80 × 30 mm or less
 Dimensions / Weight  283(L) × 143(W) × 50(D) mm / Approx. 590g (including batteries)
 Applicable Standards

 IEC 61010-1,
 IEC 61010-2-032 (main unit) / IEC 61010-031 (test leads)
 CAT IV 600 V / CAT III 1000 V Pollution degree 2,
 IEC 61326 (EMC) Class B, EN50581 (RoHS), EN 301 489-1,
 EN 300 328, EN 62479, IEC 60529 (IP40)

 Included Accessories

 7290 (Test leads)
 9198 (Soft Case)
 LR6(AA)×2, Instruction Manual

※1 Bluetooth is a trademark or registered trademark of Bluetooth SIG. Inc. Android is a trademark or registered trademark of Google Inc. iOS is a trademark or registered trademark of Cisco Technology, Inc. in the United States and other countries.

 

Accessories

Back To top