Quality and reliability is our tradition
Our Products
MODEL 2002R
AC Digital Clamp Meters MODEL 2002R

AC Digital Clamp Meters

MODEL 2002R

 
• Can measure large AC current up to 2000A.
• Peak hold function.
• 55mm-dia large teardrop-shaped jaws.
 
  • TRUE RMS  φ55  MAX2000A  ACV  DCV  Resistance  PeakHold10ms  OutPut  Continuitybuzzer

     
    AC A 400A (0 - 400A)
    ±1.5%rdg±3dgt [45 - 65Hz]
    ±2.5%rdg±3dgt [40Hz - 1kHz]
    2000A (0 - 1500A)
    ±2%rdg±5dgt [45 - 65Hz]
    ±3%rdg±5dgt [40Hz - 1kHz]
    2000A (1501 - 2000A)
    ±4%rdg [50/60Hz]
    AC V 40/400/750V
    ±1%rdg±2dgt [45 - 65Hz]
    ±1.5%rdg±3dgt [40Hz - 1kHz]
    DC V 40/400/1000V ±1%rdg±2dgt
    Ω 400Ω/4k/40k/400kΩ ±1.5%rdg±2dgt
    Continuity buzzer buzzer sounds below 50±35Ω
    Conductor size Ø55mm max.
    Frequency response 40Hz - 1kHz
    Output Recorder :
    DC400mV against AC400A
    DC200mV against AC2000A
    Safety Standard IEC 61010-1 CAT III 600V, CAT II 1000V
    IEC 61010-2-031
    IEC 61010-2-032
    Power source R6 (AA) (1.5V) × 2
    Dimensions 247(L) × 105(W) × 49(D)mm
    Weight 470g approx.
    Included Accessories 7107A (Test leads)
    9094 (Carrying Case)
    R6 (AA) × 2
    Instruction Manual
    Optional Accessories 7256 (Output cord)
     
     

    Accessories/Optional Accessories /Related Products

    MODEL 7107A     MODEL 7107A

     

     

                                                   MODEL 7256      MODEL 7256

Download File
Instruction Manual
Contact Dealer

Thai Electricity International Co.,Ltd.
Tel: 02-918-1999 / Email: info@thaielectrics.com

 

SCM PREMIER Co.,Ltd.
Tel: 02-615-5222 / Email: sales@scmpremier.com